: : OPERATION : :
The
dump loading procedure may be used, if the ampoules/vials are received
in ready to dump boxes, which will have exactly into the same number of
ampoules/vials and the pitch, as the loading tray. Alternatively, each
ampoules/vial have to be arranged in to the tray.
The
loading tray/trays are placed directly in to the machine & the
handle bar is lowered for automatic centering of washing needles in to
the ampoule / vial mouths. The top cover is also lowered & switch
is operated for automatic sequencial washing both from inside &
outside of each individual ampoule / vial.
The
machine will automatically stop after one complete cycle & for
removal of trays, reverse procedure is to be observed. Depending on
dump loading or individual loading & operator’s efficiency one can
derive as high as 30 to 40 loadings of tray/trays per hour. |