Fluid Bed Dryer Selection of capacity of fluid bed
dryer depends upon bulk density, drying temperature and moisture
contents of wet material to be dried. In case of 120 kg. Model a batch
of 145 kg. Wet material can be loaded provided the bulk density of the
material is 0.6 kg./lit. (Approx). Pharmaceutical granules with 20-25%
moisture can be dried in 30-45 minutes at 80 C approximately.
This pharma equipment machine is provided with fully automatic control
panel box with process timer, pneumatic finger bag shaking, pneumatic
lifting of container, digital temperature controller cum indicator,
voltmeter, ammeter, earthing system etc.
Optional
Available in Standard and GMP model
with SS 304 / SS 316 quality
- Pneumatic container lifting and bag arrangement.
- Instrinsically safe earthing system.
- Instrinsically safe earthing system.
- Hepa filters can be provided on demand.
Salient Features
- Better productivity and lesser drying time with less handling.
More hygienic.
- Uniform drying at low temperature.
- Static grounders to eliminate electro static charges.
- SS Product container with trolley & tilting arrangement
- Models available from 2 kgs. To 300 kgs. Capacity.
Technical Specifications
| FBD(Capacity in kgs.) |
10 |
30 |
60 |
120 |
150 |
200 |
250 |
| Capacity of Containers in litres |
35 |
100 |
215 |
430 |
650 |
780 |
950 |
| Motor H.P. |
1.5 |
5 |
10 |
15 |
20 |
20 |
25 |
| Heating Capacity KW |
6 |
18 |
36 |
60* |
* |
* |
* |
| Steam Consumption Kg/hr at 3 Kg cm pressure |
14 |
25 |
50 |
120 |
150 |
175 |
200 |
| Approx. dimension: length (in2mm) |
650 |
1400 |
1600 |
1900 |
2100 |
2150 |
2250 |
| width (in mm) |
750 |
1025 |
1200 |
1600 |
1800 |
1850 |
1900 |
| height (in mm) |
1550 |
220 |
2650 |
3200 |
3400 |
3500 |
3500 |
Note : Electrical Heating is not advisable
|